4、温控卡、时序卡、温控箱、时序控制器均可做贴牌,或按客户要求定单生产。
First, the temperature control box before the use of the confirmation:
Temperature control box in connection and use, must confirm the following matters, in order to ensure that the cause of the person to avoid temperature
Damage to the control box and personal accident:
1, check the thermocouple on the mold and the thermocouple type is consistent, that is, "J" or "K" type
Must be consistent.
2. Check the connection mode of hot runner on the die and the connection way of the box on the temperature control box.
Is the thermocouple positive and negative poles are consistent.
3, check with the cable is applicable to the temperature control box, junction box, inside of the wire and power
Even if the line is matched.
4, check the temperature control box of the input power cable wiring is correct.
5, check the resistance and insulation of the hot runner heater, and then check whether the thermocouple short circuit or circuit breaker.
6, die attached to the injection molding machine to connect the cable.
7, check the temperature control box of the total power switch and the switch of each group is closed, it should be closed in advance to avoid
Once the power supply is connected to the fault of the thermal control box or hot runner thermocouple.
8, detection of the temperature control box is connected to the input power supply is suitable for temperature control box, and then connect the cable.
9, to ensure that the grounding wire firmly connected to the temperature control box.
10, open the main power switch.
11, open a single set of switches: first open a group, then a group of gradually open, so as to ensure that if the wrong
Line, only to burn a group of temperature control card or a group of thermocouple. If there is an abnormal sound or display, please do not
To continue to open the other temperature control card, should immediately check the various parts of the wiring.
12, each set to the required temperature.
13, check whether the required temperature and stability.
14, note: in the plug temperature control card must first be temperature control box power off.
Using ambient temperature: 0 degrees C----55 degrees C
Type of temperature sensor: J type or K type thermocouple
Temperature control range: 0 degrees C----537 degrees C (0-999? F)
Temperature control accuracy: + 1 degrees C
Control output form: silicon controlled (Triac) output
Output: 3600W AC220V/15A
Input power: 50/60Hz AC85----400V
Note:
1, plug temperature control box 1-30 has finished 32 points more than the required custom spot.
2, temperature control box with accessories: Germany SIEMENS circuit breaker, Taiwan imported fans, Italy GW connector.
3, temperature control box wiring way: 1, 2 heating cycles 3, 4 (3+, 4-) thermocouple; according to customer requirements wiring.
4, temperature control card, timing card, temperature control box, a timing controller can do OEM, or according to customer requirements and production orders.